Skip to content
Surf Wiki
Save to docs
general/dosimeters

From Surf Wiki (app.surf) — the open knowledge base

Personal RF safety monitor

Personal RF safety monitor

Electromagnetic field monitors measure the exposure to electromagnetic radiation in certain ranges of the electromagnetic spectrum. This article concentrates on monitors used in the telecommunication industry, which measure exposure to radio spectrum radiation. Other monitors, like extremely low frequency monitors which measure exposure to radiation from electric power lines, also exist. The major difference between a "Monitor" and a "Dosimeter" is that a Dosimeter can measure the absorbed dose of ionizing radiation, which does not exist for RF Monitors. Monitors are also separated by "RF Monitors" that simply measure fields and "RF Personal Monitors" that are designed to function while mounted on the human body.

Introduction

A comprehensive view of personal RF monitors
Personal RF monitor comparison

Electromagnetic field monitors, as used in the cellular phone industry, are referred as "personal RF safety monitors", personal protection monitors (PPM) or RF exposimeters. They form part of the personal protective equipment worn by a person working in areas exposed to radio spectrum radiation. A personal RF safety monitor is typically worn either on the torso region of the body or handheld and is required by the occupational safety and health acts of many telecommunication companies.

Most of the scientifically proven RF safety monitors are designed to measure the RF exposure as a percentage of the two most common international RF safety guidelines: International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines and the U.S. Federal Communications Commission (FCC). The ICNIRP guidelines are also endorsed by the WHO. RF personal safety monitors were originally designed for RF Engineers working in environments where they could be exposed to high levels of RF energy or be working close to a RF source, for example working at the top of a telecommunication tower, or working on the rooftop of a building where transmitting antennas are present. Most international RF safety programs include the training and use of RF personal safety monitors and the IEEE C95.7 specifies what is a RF Personal Monitor.

In some cases the RF safety monitor comes in a version or mode for the general public. These meters can then be used to determine areas where the public might be exposed to high levels of RF energy or used to indicate the RF level in areas where the general public has access.

Specification

The specifications of a RF monitor determines the work environment where could be applicable. Wideband RF monitors can be used at a broader variety of base station sites than for example a narrowband, cellular RF monitor which is designed only to be used in the mobile telephone- and data networks. IEEE Std C95.3 states that "In the region between 1-100 GHz, resistive thermoelectric dipoles are used as sensors with a background of lossy material to reduce the effect of scattering from the body. Electrically short dipoles with diode detectors as sensors may cover a portion of this range". The results of monitors which do not incorporate "lossy material" to reduce the effects of scattering, are questionable on the body.

The type of response is a basic feature of any RF personal monitor and can be expressed in two basic parameters:

  • Directivity: Some of them have an isotropic response, which means that they are able to measure RF fields from any space direction. Others, like radial field monitors, have a partial space coverage, and have to be worn in a specific way in order to provide a correct reading.
  • Frequency response:
    • Flat response: units that have a flat response for all the frequency range covered, i.e. the response does not change with frequency.
    • Shaped response: contain frequency dependent sensors that automatically weight the detected RF fields in accordance with frequency-dependent RF exposure limits.

It is common that RF personal monitors provide results as a percentage (%) of frequency-dependent limit values of a specific standard (sometimes called reference levels or MPE, maximum permissible exposure). It is important to be careful interpreting exposure during an alarm condition based on a % result; shaped response RF personal monitors will provide a result as a % of the standard, independently of the frequency, while flat response monitors will provide a result as a % of a particular value (not frequency-dependent), so it is important to know which is the particular value this % is referring to.

Some RF personal monitors have different versions, shaped to each standard, so they will be more accurate, but can be used only for that standard. Others have a single version, so will be less accurate, but can be used for different standards.

Usually, the alarm of most RF personal monitors is triggered by instant values, however, standard limits are specified as time-averaged values. Some RF monitors have the possibility to trigger alarms based on average values, which is a better indication of the real exposure situation (as an example, an instant value can be at 200% while the average being below 100%).

As they are typically small, portable units, they are usually equipped with only a few LEDs for a rough field level indication (50%, 100%, etc). Nevertheless, some of them have a datalogger that allows to download the measurements, check for the exact values, and keep a history record of the exposures. Wavecontrol's WaveMon has available a GPS and altimeter to include position information to the data records.

Other specifications that may be relevant, depending on the application are battery characteristics (lifetime, ways to change or recharge), dimensions, weight, and operating temperature.

The following table shows different basic specifications of some RF monitors:

Specificationurl=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xstitle=EME Guard XSwebsite=RF Monitors EME Guard XSpublisher=mvg-world.comaccessdate=2020-06-11}}url=https://www.narda-sts.us/pdf_files/RadManXT-p76.pdftitle=Narda STS RadMan XT Datasheetlast=first=date=website=publisher=Narda-sts.usaccessdate=2012-06-06}}url=https://www.narda-sts.com/en/personal-safety-emf/radman-2-xt-/-radman-2-lt/title=Narda Radman 2last=first=date=website=publisher=Narda-sts.comaccessdate=2023-08-11}}'''Narda RadMan 2XTWaveMon RF-8url=http://www.lbagroup.com/products/safeone-rf-monitorstitle = SafeOnePRO Personal RF Safety Monitor PPE: Light, Tuff, All Cell Band}}fieldSENSE 2.0date=title=FieldSENSEurl=https://fieldsense.com/fieldsense-60-data-sheet/accessdate=2025-01-30publisher=FieldSENSE}}url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-plustitle=EME Guard Pluswebsite=RF Monitors EME Guard Pluspublisher=mvg-world.comaccessdate=2020-06-11}}WaveMon RF-60url=http://www.narda-sts.us/pdf_files/DataSheets/NardalertS3_DataSheet.pdftitle=Narda Safety Test Solutions Nardalert S3 Datasheetpublisher=Narda-sts.usdate=accessdate=2016-06-06}}url=https://www.mvg-world.com/products/rf-safety/occupational-rf-safety/eme-guard-xs-40-ghztitle=MVG OCCUPATIONAL RF SAFETY-EME Guard XS 40GHzpublisher=mvg-world.comdate=accessdate=2021-05-05}}
Frequency Range80 MHz – 6 GHzE-FieldE-FieldE-FieldE-Field: 300 kHz - 8 GHz10-10000 MHzE-Field 50 MHz - 6 GHzE-Field 50 MHz - 60 GHz1 MHz- 40 GHzE-Field: 100 kHz - 60 GHz100 kHz – 100 GHz1 MHz – 40 GHz
DirectivityIsotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Isotropic (Tri-axial)Radial and Dual-polarizedIsotropic (Tri-axial)
Frequency ResponseFlatShapedShapedShapedShapedFlatShapedShapedFlatShapedShapedFlat
50/60 Hz immunityN/A1 kV/m10 kV/m10 kV/m30 kV/mN/AN/AN/AN/A30 kV/m100 kV/mN/A
Designed to be worn on the Body (per IEEE C95.3)NoYesYesYesYesNoYesYesNoYesYesNo
Reference standardICNIRP 2020ICNIRPICNIRPICNIRPFCCICNIRPICNIRPICNIRPICNIRP 2020FCCFCCICNIRP 2020
Exposure level indicators1 X LED = 1%1 X LED = 12.5%1 X LED = 5%1 X LED = 5%1 X LED = 10%1 X LED = 2%1 X LED = 2%1 x LED= 6%1 X LED = 10%LED Display of the Actual Value1 X LED = 0.4%
Data loggerNoYesYesYesYesNoYesYesYesYesYes (Option)No
GPSNoNoNoNoYesNoNoNoNoYesNoNo
AltimeterNoNoNoNoYesNoNoNoNoYesNoNo
Battery life100 hours200 hours800 hours800 hours200 hours (Rechargeable via USB)2,000 hours6-12 months average use6 to 12 months on ave usage6-12 months average useRecording mode:200 hours (Rechargeable via USB)25 hours (Rechargeable via USB)1000 hours
Dimensions132.5 x 48.5 x 28.7 mm163 x 41 x 37 mm165 x 47 x 31 mm165 x 47 x 31 mm174 x 42.5 x 33 mm58 x 105 x 23 mm146 X 42 X 26 mm146 X 42 X 26 mm172.6 X 59 X 35.5 mm174 x 42.5 x 33 mm117 x 83 x 32 mm132.5 x 48.5 x 28.7 mm ( LxWxH)
Weight120g130g185g185g190g88g115 g115 g275g190g230g120 g
Operating temperature-10°C to +50°C-10°C to + 55°C-10°C to + 55°C-10°C to + 55°C-20 °C to +50 °C-10°C to +40°C-20 °C to +50 °C-20 °C to +50 °C-20°C to +55°C-20 °C to +50 °C-10°C to +50°C-10°C to +50°C
Calibration interval24 Months36 months36 months36 months24 Months24 Months36 Months36 Months24 Months24 Months48 months24 Months
NIST/ILAC Traceable CalibrationNoYesYesYesYesNoYesYesNoYesYesNo
Fall Detection AlarmNoNoNoNoYesNoYesYesNoYesNoNo
Approx. price USD$550$1000$600$1200$900$700$599$799$999$1400$1700$799

Operating instructions

Each specific personal RF safety monitor has its own operating instructions. And most of the monitors have different operating modes. For instance, the Narda Radman has a mode in which it can be body worn by the operator, but it also has a probe mode where the operator can scan certain areas to find accurate exclusion zones. The FieldSENSE on the other hand has a monitor and measure mode. The measure mode is similar to the Radman's probe mode, but the monitor mode is used by mounting the FieldSENSE onto an inactive antenna and then it is safe to work on the antenna until the FieldSENSE raise an alarm to warn RF technicians that the antenna is live and that any work on the antennas should be ceased until deactivation is confirmed. The Wavecontrol's WaveMon and Narda's RadMan 2[29] can be body-worn, and used off the body as a probe or as a monitor. Most of the RF monitors such as the FieldSENSE, EME Guard, WaveMon and the RadMan 2 also have a data logging functionality that can log the RF exposure of a worker over time. The RadMan 2XT's RF detection mode with its tone search feature can locate leaks in waveguides and verify that an antenna is turned off. [30]

List of personal RF monitors

  • EME Guard Plus
  • EME Guard XS
  • EME Guard XS 40 GHz
  • EME SPY Evolution
  • Narda Radman XT
  • Narda RadMan 2LT
  • Narda RadMan 2XT
  • Nardalert S3
  • FieldSENSE60
  • FieldSENSE 2.0
  • Public FieldSENSE
  • SafeOne Pro SI-1100XT
  • WaveMon RF-8
  • WaveMon RF-60

References

https://www.wavecontrol.com/rfsafety/images/data-sheets/en/WaveMon_Datasheet_EN.pdf

References

  1. (2007). "National Association of Broadcasters Engineering Handbook". Taylor & Francis.
  2. "OSHA Technical Manual (OTM) {{pipe".
  3. (19 December 2014). "Equipment Authorization - Measurement Procedures".
  4. (2001-12-10). "WHO/ICNIRP Conference on EMF Biological Effects". World Health Organization.
  5. [https://ieeexplore.ieee.org/document/1611107/ IEEE]. title"IEEE Recommended Practice for Radio Frequency Safety Programs, 3 kHz to 300 GHz," IEEE, International Committee on Electromagnetic Safety, New York, IEEE Std C95.7, 2014
  6. "Public product info". FieldSENSE.
  7. "EME Guard XS". mvg-world.com.
  8. "Narda STS RadMan XT Datasheet". Narda-sts.us.
  9. "Narda Radman 2". Narda-sts.com.
  10. "WaveMon RF-8. Broadband Personal monitor".
  11. "SafeOnePRO Personal RF Safety Monitor PPE: Light, Tuff, All Cell Band".
  12. "FieldSENSE". FieldSENSE.
  13. "EME Guard Plus". mvg-world.com.
  14. "WaveMon RF-60 - 60 GHz RF Personal Monitor".
  15. "Narda Safety Test Solutions Nardalert S3 Datasheet". Narda-sts.us.
  16. "MVG OCCUPATIONAL RF SAFETY-EME Guard XS 40GHz". mvg-world.com.
  17. "Radman - Measure and probe mode".
  18. "FieldSENSE - Measure and monitor mode".
  19. "WaveMon RF personal monitors".
  20. "Narda Safety Test Solutions". Narda-sts.us.
  21. "EME Guard". mvg-world.com.
  22. (2020-06-11). "EME Guard Plus - MVG (Satimo)". mvg-world.com.
  23. (2020-06-11). "EME Guard XS - MVG (Satimo)". mvg-world.
  24. (2020-06-11). "EME Guard XS 40 GHz- MVG (Satimo)". mvg-world.
  25. "EME SPY evolution - MVG (Satimo)".
  26. (2011-06-06). "Narda Radman XT". Narda-sts.us.
  27. (2016-06-06). "Nardalert S3 - Narda STS". Narda-sts.us.
  28. "FieldSENSE 60 {{!}} Fieldsense".
  29. "fieldSENSE 2.0 data sheet". FieldSENSE.
  30. Broadband Personal Monitor. "Data Sheet WaveMon RF-8".
  31. 60 GHz RF Personal Monitor. "Data Sheet WaveMon RF-60".
Info: Wikipedia Source

This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.

Want to explore this topic further?

Ask Mako anything about Personal RF safety monitor — get instant answers, deeper analysis, and related topics.

Research with Mako

Free with your Surf account

Content sourced from Wikipedia, available under CC BY-SA 4.0.

This content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.

Report