Skip to content
Surf Wiki
Save to docs
general/ophthalmology

From Surf Wiki (app.surf) — the open knowledge base

Golovin–Sivtsev table

Standardized table for testing visual acuity

Golovin–Sivtsev table

Standardized table for testing visual acuity

FieldValue
nameGolovin–Sivtsev table
imageGolovin-Sivtsev Table.svg
purposetesting visual acuity
DiseasesDB
ICD10
MedlinePlus
eMedicine
OPS301
LOINC

The Golovin–Sivtsev table () is a standardized table for testing visual acuity, which was developed in 1923 by Soviet ophthalmologists Sergei Golovin and D. A. Sivtsev. In the USSR, it was the most common table of its kind, and its use is still widespread in several post-Soviet states.

The table consists of two parts with 12 rows each, representing visual acuity values between 0.1 and 2.0. The left part consists of series of the Cyrillic letters Ш, Б, М, Н, К, Ы, and И in a definite order, and the right part of the table consists of a series of Landolt C symbols. The width of each character is equal to its height, and the contours have standard gaps of the overall size.

The value D, indicated to the left of each row, gives the distance in meters from which a person with a visual acuity of 1.0 can read the corresponding row. The value V, indicated to the right, gives the minimum visual acuity needed to read the row from a distance of 5 meters. The first row contains symbols 70 mm in size (V = 0.1); the second row, 35 mm; the bottom third row, 7 mm (V = 1.0); the bottom row, 3.5 mm (V = 2.0).

Black and white pattern identification at 1 arcminute angle is considered to be visual acuity of 1.0, which is around 1 mm per 3.44 m distance. A character 7 mm in size has 1.4 mm pattern gaps, so over the 5 m view distance it gives an angle of around 1 arcminutes (atan(0.007/5/5)≈0.963').

There are two types of the table. The first is shorter, second is longer version.

References

References

  1. {{in lang. ru [http://www.ochki.net/articles/article-18-141.html Refraction and acuity] {{Webarchive. link. (2012-04-21)
  2. {{in lang. ru [http://medarticle30.moslek.ru/articles/40823.htm Golovin–Sivtsev table for determining the visual acuity] {{Webarchive. link. (2008-06-05)
  3. {{in lang. ru [http://nekin.narod.ru/siv/siv.htm Some information on Golovin–Sivtsev table] {{Webarchive. link. (2008-12-01 — that website as a whole doesn't seem to be reliable, but it seems to present reliable information on Golovin-Sivtsev table dimensions)
Info: Wikipedia Source

This article was imported from Wikipedia and is available under the Creative Commons Attribution-ShareAlike 4.0 License. Content has been adapted to SurfDoc format. Original contributors can be found on the article history page.

Want to explore this topic further?

Ask Mako anything about Golovin–Sivtsev table — get instant answers, deeper analysis, and related topics.

Research with Mako

Free with your Surf account

Content sourced from Wikipedia, available under CC BY-SA 4.0.

This content may have been generated or modified by AI. CloudSurf Software LLC is not responsible for the accuracy, completeness, or reliability of AI-generated content. Always verify important information from primary sources.

Report